Diode Laser Hair Removal Machine
-
808nm Laser Hair Removal Machine
-
Permanent Laser Hair Removal Machine
-
HIFU Face Lift Machine
-
Muscle Sculpting Machine
-
RF Microneedling Machine
-
Facial Skin Care Machines
-
IPL Photofacial Machine
-
CO2 Fractional Laser Machine
-
Cellulite Reduction Machine
-
Cryolipolysis Fat Freeze Slimming Machine
-
Q Switched ND Yag Laser Tattoo Removal Machine
-
PDT LED Light Therapy Machine
-
Magic Mirror Skin Analyzer Machine
-
DAIKI *****Their service was excellent. After I received the machine, they helped me get familiar with how to operate it.
-
ILYA ******The machine is great. Every time I have a question, they will reply me quickly.
Man Medical Q Switched ND Yag Laser Tattoo Removal Machine Stationary Style

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Q Switch ND YAG Laser System | Keyword | Q Switched Nd Yag Laser Tattoo Removal |
---|---|---|---|
Q-Switch | YES | Style | Stationary |
Wavelength | 1064nm/532nm | Pulse Energy | 500mJ/200mJ |
Fluence | 0.2-16J/cm2, 0.1-6.3J/cm2 | After-sales Service Provided | Free Spare Parts, Online Support, Video Technical Support And Etc. |
Treatment Of Vascular Lesions | Port Wine Birthmarks; Spider Angioma | ||
High Light | Man Q Switched ND Yag Laser Tattoo Removal Machine,Medical Q Switched ND Yag Laser Tattoo Removal Machine,ND YAG Q Switch Laser Machine |
Professional For Man Medical Q Switched Nd Yag Laser Tattoo Removal Machine
Side Effects and Taboos
For the darker skin patient, it is not suggestible to randomly adopt high energy because the superficial skin layer pigment’s absorption of laser makes it relatively higher risk if the skin is lightly damaged.
The skin may appear red and swollen, skin infiltration of blood and inflammatory reactions after the laser operation. Unguent for scald and scar avoidance shall be used after treatment.
For parts of pigments which contains metal ion (such as iron ion), some of dark chemicals (like ferrous oxide), which are difficult to be absorbed after laser treatment, may darker treatment areas. This is caused by different structures of pigments, which has no relations to the device quality.
Keep the treatment area dry and clean and protect it from infection.
Treatment Principle
Treatment principle of Monaliza-2 Q-Switched Nd:YAG Laser Therapy System is based on laser selective photothermy and blasting mechanism of Q-switched laser.Energy from particular wavelength with accurate dose will act on certain targeted color radicals:ink,carbon particles from derma and epidermis,exogenous pigment particles and endogenous melanophore from derma and epidermis.When suddenly being heated,Pigment particles immediately blast into smaller pieces, which will be swallowed by macrophage phagocytosis and enters into lymph circulation system and finally be discharged out of body.
Introduction
ExQ-Laser is the newest generation Q-switched laser treatment system developed by Sincoheren, which possesses laser output with wave length 1064nm and 532nm. The laser
can reach max. 600mj under min. pulse width 5ns, such optimized configuration has achieved
great clinical effect. With focused and detailed design the laser system could calibrate automatically and is fully under real time supervision.
ExQ-Laser is functionally outstanding, safely stable and has been approved by CFDA and European Medical CE. The unique design has gained couple of global patent protections.
Specification:
Laser Type | Q-Switched Nd YAG |
Wavelength | 1064nm,532 nm |
Pulse Width | 5ns |
Pulse Energy | 500mj; 200mj |
Pulse Energy Range | 200-500mj;100-200mj |
Fluence | 0.2-16j/cm2; 0.1-6.3j/cm2 |
Frequency | 5Hz |
Spot size | 2-10mm adjustable |
Aiming Beam | 635mm,<5mW |
Electrical | 110-240VAC, 50-60Hz,1200VA |
Dimension | 35.1cm*92.5cm*77.5cm (artculated arm not included) |
Net weight | 80kg |
High energy Q switched Nd | 1000mj optional |
1. US(K163123) CE TGA approved--best quality and results guaranteed
2. Two stages Nd:YAG laser system with electro-optic Q-switched technology, which output higher energy. The designs adopt cavity optimozed schedule, make the pulse width as short as 5ns, get doubled output power density under the same energy.
3. Integrated laser edergy monitor system inside, set warning signal when energy deviation over threshold, all to ensure treatment effectiveness and safety.
4. Seven joints optical articulated arm with adjustable hadnpieces, spot size setting from 2 to 10mm. The energy synchronously changer following the setting spot size.
Firstly, the laser is absorbed by according pigments or ink;Secondly, the pigment mass expands quickly and break into particles; Thirdly, particles are absorbed by phagocytes, and excreted out by body; Finally, gradually the pigment becomes lighter and lighter till disappearing.
Curing range Pigment pathology of skin, for instance, the blue, black, red, brown or mixture of eyebrow lines, eyelid-lines and tattoos, including flecks.